Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Magn Reson Chem ; 62(6): 429-438, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38230451

RESUMEN

In recent years there has been a renewed interest in benchtop NMR. Given their lower cost of ownership, smaller footprint, and ease of use, they are especially suited as an educational tool. Here, a new experiment targeted at upper-year undergraduates and first-year graduate students follows the conversion of D-glucose into ethanol at low-field. First, high and low-field data on D-glucose are compared and students learn both the Hz and ppm scales and how J-coupling is field-independent. The students then acquire their own quantitative NMR datasets and perform the quantification using an Electronic Reference To Access In Vivo Concentration (ERETIC) technique. To our knowledge ERETIC is not currently taught at the undergraduate level, but has an advantage in that internal standards are not required; ideal for following processes or with future use in flow-based benchtop monitoring. Using this quantitative data, students can relate a simple chemical process (fermentation) back to more complex topics such as reaction kinetics, bridging the gaps between analytical and physical chemistry. When asked to reflect on the experiment, students had an overwhelmingly positive experience, citing agreement with learning objectives, ease of understanding the protocol, and enjoyment. Each of the respondents recommended this experiment as a learning tool for others. This experiment has been outlined for other instructors to utilize in their own courses across institutions, with the hope that a continued expansion of low-field NMR will increase accessibility and learning opportunities at the undergraduate level.


Asunto(s)
Espectroscopía de Resonancia Magnética , Espectroscopía de Resonancia Magnética/métodos , Etanol/química , Glucosa/análisis , Estudiantes , Humanos , Universidades
2.
Magn Reson Chem ; 62(6): 463-473, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38282484

RESUMEN

Benchtop NMR provides improved accessibility in terms of cost, space, and technical expertise. In turn, this encourages new users into the field of NMR spectroscopy. Unfortunately, many interesting samples in education and research, from beer to whole blood, contain significant amounts of water that require suppression in 1H NMR in order to recover sample information. However, due to the significant reduction in chemical shift dispersion in benchtop NMR systems, the sample signals are much closer to the water resonance compared to those in a corresponding high-field NMR spectrum. Therefore, simply translating solvent suppression experiments intended for high-field NMR instruments to benchtop NMR systems without careful consideration can be problematic. In this study, the effectiveness of several popular water suppression schemes was evaluated for benchtop NMR applications. Emphasis is placed on pulse sequences with no, or few, adjustable parameters making them easy to implement. These fall into two main categories: (1) those based on Pre-SAT including Pre-SAT, PURGE, NOESY-PR, and g-NOESY-PR and (2) those based on binomial inversion including JRS and W5-WATERGATE. Among these schemes, solvent suppression sequences based on Pre-SAT offer a general approach for easy solvent suppression for samples with higher analyte concentrations (sucrose standard and Redbull™). However, for human urine, binomial-like sequences were required. In summary, it is demonstrated that highly efficient water suppression approaches can be implemented on benchtop NMR systems in a simple manner, despite the limited spectral dispersion, further illustrating the potential for widespread implementation of these approaches in education and research.

3.
Magn Reson Chem ; 62(5): 345-360, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37811556

RESUMEN

Understanding environmental change is challenging and requires molecular-level tools to explain the physicochemical phenomena behind complex processes. Nuclear magnetic resonance (NMR) spectroscopy is a key tool that provides information on both molecular structures and interactions but is underutilized in environmental research because standard "high-field" NMR is financially and physically inaccessible for many and can be overwhelming to those outside of disciplines that routinely use NMR. "Low-field" NMR is an accessible alternative but has reduced sensitivity and increased spectral overlap, which is especially problematic for natural, heterogeneous samples. Therefore, the goal of this study is to investigate and apply innovative experiments that could minimize these challenges and improve low-field NMR analysis of environmental and biological samples. Spectral simplification (JRES, PSYCHE, singlet-only, multiple quantum filters), selective detection (GEMSTONE, DREAMTIME), and heteronuclear (reverse and CH3/CH2/CH-only HSQCs) NMR experiments are tested on samples of increasing complexity (amino acids, spruce resin, and intact water fleas) at-high field (500 MHz) and at low-field (80 MHz). A novel experiment called Doubly Selective HSQC is also introduced, wherein 1H signals are selectively detected based on the 1H and 13C chemical shifts of 1H-13C J-coupled pairs. The most promising approaches identified are the selective techniques (namely for monitoring), and the reverse and CH3-only HSQCs. Findings ultimately demonstrate that low-field NMR holds great potential for biological and environmental research. The multitude of NMR experiments available makes NMR tailorable to nearly any research need, and low-field NMR is therefore anticipated to become a valuable and widely used analytical tool moving forward.


Asunto(s)
Aminoácidos , Espectroscopía de Resonancia Magnética
4.
Anal Chem ; 95(37): 13932-13940, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37676066

RESUMEN

In environmental research, it is critical to understand how toxins impact invertebrate eggs and egg banks, which, due to their tiny size, are very challenging to study by conventional nuclear magnetic resonance (NMR) spectroscopy. Microcoil technology has been extensively utilized to enhance the mass-sensitivity of NMR. In a previous study, 5-axis computer numerical control (CNC) micromilling (shown to be a viable alternative to traditional microcoil production methods) was used to create a prototype copper slotted-tube resonator (STR). Despite the excellent limit of detection (LOD) of the resonator, the quality of the line shape was very poor due to the magnetic susceptibility of the copper resonator itself. This is best solved using magnetic susceptibility-matched materials. In this study, approaches are investigated that improve the susceptibility while retaining the versatility of coil milling. One method involves machining STRs from various copper/aluminum alloys, while the other involves machining ones from an aluminum 2011 alloy and electroplating them with copper. In all cases, combining copper and aluminum to produce resonators resulted in improved line shape and SNR compared to pure copper resonators due to their reduced magnetic susceptibility. However, the copper-plated aluminum resonators showed optimal performance from the devices tested. The enhanced LOD of these STRs allowed for the first 1H-13C heteronuclear multiple quantum coherence (HMQC) of a single intact 13C-labeled Daphnia magna egg (∼4 µg total biomass). This is a key step toward future screening programs that aim to elucidate the toxic processes in aquatic eggs.


Asunto(s)
Aluminio , Cobre , Animales , Aleaciones , Biomasa , Daphnia
5.
Anal Chem ; 95(16): 6709-6717, 2023 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-37037008

RESUMEN

Chemical characterization of complex mixtures by Nuclear Magnetic Resonance (NMR) spectroscopy is challenging due to a high degree of spectral overlap and inherently low sensitivity. Therefore, NMR experiments that reduce overlap and increase signal intensity hold immense potential for the analysis of mixtures such as biological and environmental media. Here, we introduce a 13C version of DREAMTIME (Designed Refocused Excitation And Mixing for Targets In Vivo and Mixture Elucidation) NMR, which, when analyzing 13C-enriched materials, allows the user to selectively detect only the compound(s) of interest and remove all other peaks in a 13C spectrum. Selected peaks can additionally be "focused" into sharp "spikes" to increase sensitivity. 13C-DREAMTIME is first demonstrated at high field strength (500 MHz) with simultaneous selection of eight amino acids in a 13C-enriched cell free amino acid mixture and of six metabolites in an extract of 13C-enriched green algae and demonstrated at low field strength (80 MHz) with a standard solution of 13C-d-glucose and 13C-l-phenylalanine. 13C-DREAMTIME is then applied at high-field to analyze metabolic changes in 13C-enrichedDaphnia magna after exposure to polystyrene "microplastics," as well as at low-field to track fermentation of 13C-d-glucose using wine yeast. Ultimately, 13C-DREAMTIME reduces spectral overlap as only selected compounds are recorded, resulting in the detection of analyte peaks that may otherwise not have been discernable. In combination with focusing, up to a 6-fold increase in signal intensity can be obtained for a given peak. 13C-DREAMTIME is a promising experiment type for future reaction monitoring and for tracking metabolic processes with 13C-enriched compounds.


Asunto(s)
Plásticos , Vino , Aminoácidos , Glucosa , Espectroscopía de Resonancia Magnética/métodos , Saccharomyces cerevisiae , Isótopos de Carbono
6.
Anal Chem ; 95(14): 5858-5866, 2023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-36996326

RESUMEN

Toxicity testing is currently undergoing a paradigm shift from examining apical end points such as death, to monitoring sub-lethal toxicity in vivo. In vivo nuclear magnetic resonance (NMR) spectroscopy is a key platform in this endeavor. A proof-of-principle study is presented which directly interfaces NMR with digital microfluidics (DMF). DMF is a "lab on a chip" method allowing for the movement, mixing, splitting, and dispensing of µL-sized droplets. The goal is for DMF to supply oxygenated water to keep the organisms alive while NMR detects metabolomic changes. Here, both vertical and horizontal NMR coil configurations are compared. While a horizontal configuration is ideal for DMF, NMR performance was found to be sub-par and instead, a vertical-optimized single-sided stripline showed most promise. In this configuration, three organisms were monitored in vivo using 1H-13C 2D NMR. Without support from DMF droplet exchange, the organisms quickly showed signs of anoxic stress; however, with droplet exchange, this was completely suppressed. The results demonstrate that DMF can be used to maintain living organisms and holds potential for automated exposures in future. However, due to numerous limitations of vertically orientated DMF, along with space limitations in standard bore NMR spectrometers, we recommend future development be performed using a horizontal (MRI style) magnet which would eliminate practically all the drawbacks identified here.


Asunto(s)
Imagen por Resonancia Magnética , Microfluídica , Espectroscopía de Resonancia Magnética/métodos , Metabolómica/métodos , Dispositivos Laboratorio en un Chip
7.
Magn Reson Chem ; 61(12): 728-739, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-36137948

RESUMEN

Superparamagnetic iron oxide nanoparticles (SPIONs) are a contaminant of emerging interest, often used in the medical field as an imaging contrast agent, with additional uses in wastewater treatment and as food additives. Although the use of SPIONs is increasing, little research has been conducted on the toxic impacts to living organisms beyond traditional lethal concentration endpoints. Daphnia magna are model organisms for aquatic toxicity testing with a well understood metabolome and high sensitivity to SPIONs. Thus, as environmental concentrations continue to increase, it is becoming critical to understand their sub-lethal toxicity. Due to the paramagnetic nature of SPIONs, a range of potential nuclear magnetic resonance spectroscopy (NMR) experiments are possible, offering the potential to probe the physical location (via imaging), binding (via relaxation weighted spectroscopy), and the biochemical pathways impacted (via in vivo metabolomics). Results indicate binding to carbohydrates, likely chitin in the exoskeleton, along with a decrease in energy metabolites and specific biomarkers of oxidative stress. The holistic NMR framework used here helps provide a more comprehensive understanding of SPIONs impacts on D. magna and showcases NMR's versatility in providing physical, chemical, and biochemical insights.


Asunto(s)
Daphnia , Imagen por Resonancia Magnética , Animales , Daphnia/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Metabolómica/métodos , Nanopartículas Magnéticas de Óxido de Hierro
8.
Anal Chem ; 94(24): 8756-8765, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35675504

RESUMEN

Comprehensive multiphase-nuclear magnetic resonance (CMP-NMR) is a non-invasive approach designed to observe all phases (solutions, gels, and solids) in intact samples using a single NMR probe. Studies of dead and living organisms are important to understand processes ranging from biological growth to environmental stress. Historically, such studies have utilized 1H-based phase editing for the detection of soluble/swollen components and 1H-detected 2D NMR for metabolite assignments/screening. However, living organisms require slow spinning rates (∼500 Hz) to increase survivability, but at such low speeds, complications from water sidebands and spectral overlap from the modest chemical shift window (∼0-10 ppm) make 1H NMR challenging. Here, a novel 13C-optimized E-Free magic angle spinning CMP probe is applied to study all phases in ex vivo and in vivo samples. This probe consists of a two-coil design, with an inner single-tuned 13C coil providing a 113% increase in 13C sensitivity relative to a traditional multichannel single-CMP coil design. For organisms with a large biomass (∼0.1 g) like the Ganges River sprat (ex vivo), 13C-detected full spectral editing and 13C-detected heteronuclear correlation (HETCOR) can be performed at natural abundance. Unfortunately, for a single living shrimp (∼2 mg), 13C enrichment was still required, but 13C-detected HETCOR shows superior data relative to heteronuclear single-quantum coherence at low spinning speeds (due to complications from water sidebands in the latter). The probe is equipped with automatic-tuning-matching and is compatible with automated gradient shimming─a key step toward conducting multiphase screening of dead and living organisms under automation in the near future.


Asunto(s)
Carbono , Agua , Isótopos de Carbono , Espectroscopía de Resonancia Magnética
9.
Anal Chem ; 94(23): 8523-8532, 2022 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-35658120

RESUMEN

Nuclear magnetic resonance (NMR) spectroscopy has played an integral role in medical and environmental metabolic research. However, smaller biological entities, such as eggs and small tissue samples, are becoming increasingly important to better understand toxicity, biological growth/development, and diseases. Unfortunately, their small sizes make them difficult to study using conventional 5 mm NMR probes due to limited sensitivity. The use of microcoil NMR holds great potential for the analysis of such samples, where the coil can be designed to match the sample size to significantly improve NMR mass sensitivity and the filling factor. Here, we compare the potential of planar and Helmholtz microcoil designs to execute complex experiments for the analysis of intact, mass-limited biological samples. The planar coil offers the advantage of an open access design, potentially allowing flow systems to be incorporated and varying sample sizes to be studied; however, its relatively inhomogeneous B1 field leads to reduced NMR performance. The Helmholtz microcoil overcomes this drawback with its symmetrical design, improving B1 homogeneity across the sample but with the caveat that the size and shape of the sample is limited to the spacing between the two parallel coils. The line shape, sensitivity, and RF performance are compared on both coils using standard samples and biological samples. This study found that the Helmholtz microcoil used here considerably outperforms the planar coil in multipulse experiments and has great potential to study complex biological samples in the 50-200 nL range.


Asunto(s)
Imagen por Resonancia Magnética , Diseño de Equipo , Espectroscopía de Resonancia Magnética/métodos
10.
Magn Reson Chem ; 60(3): 386-397, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34647646

RESUMEN

Microcoils provide a cost-effective approach to improve detection limits for mass-limited samples. Single-sided planar microcoils are advantageous in comparison to volume coils, in that the sample can simply be placed on top. However, the considerable drawback is that the RF field that is produced by the coil decreases with distance from the coil surface, which potentially limits more complex multi-pulse NMR pulse sequences. Unfortunately, 1 H NMR alone is not very informative for intact biological samples due to line broadening caused by magnetic susceptibility distortions, and 1 H-13 C 2D NMR correlations are required to provide the additional spectral dispersion for metabolic assignments in vivo or in situ. To our knowledge, double-tuned single-sided microcoils have not been applied for the 2D 1 H-13 C analysis of intact 13 C enriched biological samples. Questions include the following: Can 1 H-13 C 2D NMR be performed on single-sided planar microcoils? If so, do they still hold sensitivity advantages over conventional 5 mm NMR technology for mass limited samples? Here, 2D 1 H-13 C HSQC, HMQC, and HETCOR variants were compared and then applied to 13 C enriched broccoli seeds and Daphnia magna (water fleas). Compared to 5 mm NMR probes, the microcoils showed a sixfold improvement in mass sensitivity (albeit only for a small localized region) and allowed for the identification of metabolites in a single intact D. magna for the first time. Single-sided planar microcoils show practical benefit for 1 H-13 C NMR of intact biological samples, if localized information within ~0.7 mm of the 1 mm I.D. planar microcoil surface is of specific interest.


Asunto(s)
Daphnia , Imagen por Resonancia Magnética , Animales , Espectroscopía de Resonancia Magnética/métodos , Resonancia Magnética Nuclear Biomolecular
11.
Anal Chem ; 93(29): 10326-10333, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-34259008

RESUMEN

Comprehensive multiphase (CMP) NMR, first described in 2012, combines all of the hardware components necessary to analyze all phases (solid, gel, and solution) in samples in their natural state. In combination with spectral editing experiments, it can fully differentiate phases and study the transfer of chemical species across and between phases, providing unprecedented molecular-level information in unaltered natural systems. However, many natural samples, such as swollen soils, plants, and small organisms, contain water, salts, and ionic compounds, making them electrically lossy and susceptible to RF heating, especially when using high-strength RF fields required to select the solid domains. While dedicated reduced-heating probes have been developed for solid-state NMR, to date, all CMP-NMR probes have been based on solenoid designs, which can lead to problematic sample heating. Here, a new prototype CMP probe was developed, incorporating a loop gap resonator (LGR) for decoupling. Temperature increases are monitored in salt solutions analogous to those in small aquatic organisms and then tested in vivo on Hyalella azteca (freshwater shrimp). In the standard CMP probe (solenoid), 80% of organisms died within 4 h under high-power decoupling, while in the LGR design, all organisms survived the entire test period of 12 h. The LGR design reduced heating by a factor of ∼3, which allowed 100 kHz decoupling to be applied to salty samples with generally ≤10 °C sample heating. In addition to expanding the potential for in vivo research, the ability to apply uncompromised high-power decoupling could be beneficial for multiphase samples containing true crystalline solids that require the strongest possible decoupling fields for optimal detection.


Asunto(s)
Calefacción , Calor , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Ondas de Radio
12.
Analyst ; 146(14): 4461-4472, 2021 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-34136891

RESUMEN

Comprehensive multiphase NMR combines the ability to study and differentiate all phases (solids, gels, and liquids) using a single NMR probe. The general goal of CMP-NMR is to study intact environmental and biological samples to better understand conformation, organization, association, and transfer between and across phases/interfaces that may be lost with conventional sample preparation such as drying or solubilization. To date, all CMP-NMR studies have used 4 mm probes and rotors. Here, a larger 7 mm probehead is introduced which provides ∼3 times the volume and ∼2.4 times the signal over a 4 mm version. This offers two main advantages: (1) the additional biomass reduces experiment time, making 13C detection at natural abundance more feasible; (2) it allows the analysis of larger samples that cannot fit within a 4 mm rotor. Chicken heart tissue and Hyalella azteca (freshwater shrimp) are used to demonstrate that phase-based spectral editing works with 7 mm rotors and that the additional biomass from the larger volumes allows detection with 13C at natural abundance. Additionally, a whole pomegranate seed berry (aril) and an intact softgel capsule of hydroxyzine hydrochloride are used to demonstrate the analysis of samples too large to fit inside a conventional 4 mm CMP probe. The 7 mm version introduced here extends the range of applications and sample types that can be studied and is recommended when 4 mm CMP probes cannot provide adequate signal-to-noise (S/N), or intact samples are simply too big for 4 mm rotors.


Asunto(s)
Imagen por Resonancia Magnética , Biomasa , Espectroscopía de Resonancia Magnética
13.
Anal Chem ; 92(23): 15454-15462, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33170641

RESUMEN

The superior mass sensitivity of microcoil technology in nuclear magnetic resonance (NMR) spectroscopy provides potential for the analysis of extremely small-mass-limited samples such as eggs, cells, and tiny organisms. For optimal performance and efficiency, the size of the microcoil should be tailored to the size of the mass-limited sample of interest, which can be costly as mass-limited samples come in many shapes and sizes. Therefore, rapid and economic microcoil production methods are needed. One method with great potential is 5-axis computer numerical control (CNC) micromilling, commonly used in the jewelry industry. Most CNC milling machines are designed to process larger objects and commonly have a precision of >25 µm (making the machining of common spiral microcoils, for example, impossible). Here, a 5-axis MiRA6 CNC milling machine, specifically designed for the jewelry industry, with a 0.3 µm precision was used to produce working planar microcoils, microstrips, and novel microsensor designs, with some tested on the NMR in less than 24 h after the start of the design process. Sample wells could be built into the microsensor and could be machined at the same time as the sensors themselves, in some cases leaving a sheet of Teflon as thin as 10 µm between the sample and the sensor. This provides the freedom to produce a wide array of designs and demonstrates 5-axis CNC micromilling as a versatile tool for the rapid prototyping of NMR microsensors. This approach allowed the experimental optimization of a prototype microstrip for the analysis of two intact adult Daphnia magna organisms. In addition, a 3D volume slotted-tube resonator was produced that allowed for 2D 1H-13C NMR of D. magna neonates and exhibited 1H sensitivity (nLODω600 = 1.49 nmol s1/2) close to that of double strip lines, which themselves offer the best compromise between concentration and mass sensitivity published to date.


Asunto(s)
Costos y Análisis de Costo , Espectroscopía de Resonancia Magnética/economía , Espectroscopía de Resonancia Magnética/instrumentación , Microtecnología/instrumentación , Animales , Daphnia/química , Diseño de Equipo , Fenómenos Mecánicos , Factores de Tiempo
14.
Anal Chim Acta X ; 6: 100051, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33392494

RESUMEN

Nuclear Magnetic Resonance (NMR) spectroscopy is a non-invasive analytical technique which allows for the study of intact samples. Comprehensive Multiphase NMR (CMP-NMR) combines techniques and hardware from solution state and solid state NMR to allow for the holistic analysis of all phases (i.e. solutions, gels and solids) in unaltered samples. This study is the first to apply CMP-NMR to deceased, intact organisms and uses 13C enriched Daphnia magna (water fleas) as an example. D. magna are commonly used model organisms for environmental toxicology studies. As primary consumers, they are responsible for the transfer of nutrients across trophic levels, and a decline in their population can potentially impact the entire freshwater aquatic ecosystem. Though in vivo research is the ultimate tool to understand an organism's most biologically relevant state, studies are limited by conditions (i.e. oxygen requirements, limited experiment time and reduced spinning speed) required to keep the organisms alive, which can negatively impact the quality of the data collected. In comparison, ex vivo CMP-NMR is beneficial in that; organisms do not need oxygen (eliminating air holes in rotor caps and subsequent evaporation); samples can be spun faster, leading to improved spectral resolution; more biomass per sample can be analyzed; and experiments can be run for longer. In turn, higher quality ex vivo NMR, can provide more comprehensive NMR assignments, which in many cases could be transferred to better understand less resolved in vivo signals. This manuscript is divided into three sections: 1) multiphase spectral editing techniques, 2) detailed metabolic assignments of 2D NMR of 13C enriched D. magna and 3) multiphase biological changes over different life stages, ages and generations of D. magna. In summary, ex vivo CMP-NMR proves to be a very powerful approach to study whole organisms in a comprehensive manner and should provide very complementary information to in vivo based research.

15.
Angew Chem Int Ed Engl ; 58(43): 15372-15376, 2019 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-31449724

RESUMEN

Microcoil nuclear magnetic resonance (NMR) has been interfaced with digital microfluidics (DMF) and is applied to monitor organic reactions in organic solvents as a proof of concept. DMF permits droplets to be moved and mixed inside the NMR spectrometer to initiate reactions while using sub-microliter volumes of reagent, opening up the potential to follow the reactions of scarce or expensive reagents. By setting up the spectrometer shims on a reagent droplet, data acquisition can be started immediately upon droplet mixing and is only limited by the rate at which NMR data can be collected, allowing the monitoring of fast reactions. Here we report a cyclohexene carbonate hydrolysis in dimethylformamide and a Knoevenagel condensation in methanol/water. This is to our knowledge the first time rapid organic reactions in organic solvents have been monitored by high field DMF-NMR. The study represents a key first step towards larger DMF-NMR arrays that could in future serve as discovery platforms, where computer controlled DMF automates mixing/titration of chemical libraries and NMR is used to study the structures formed and kinetics in real time.

16.
Lab Chip ; 19(4): 641-653, 2019 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-30648175

RESUMEN

In recent years microcoils and related structures have been developed to increase the mass sensitivity of nuclear magnetic resonance spectroscopy, allowing this extremely powerful analytical technique to be extended to small sample volumes (<5 µl). In general, microchannels have been used to deliver the samples of interest to these microcoils; however, these systems tend to have large dead volumes and require more complex fluidic connections. Here, we introduce a two-plate digital microfluidic (DMF) strategy to interface small-volume samples with NMR microcoils. In this system, a planar microcoil is surrounded by a copper plane that serves as the counter-electrode for the digital microfluidic device, allowing for precise control of droplet position and shape. This feature allows for the user-determination of the orientation of droplets relative to the main axes of the shim stack, permitting improved shimming and a more homogeneous magnetic field inside the droplet below the microcoil, which leads to improved spectral lineshape. This, along with high-fidelity droplet actuation, allows for rapid shimming strategies (developed over decades for vertically oriented NMR tubes) to be employed, permitting the determination of reaction-product diffusion coefficients as well as quantitative monitoring of reactive intermediates. We propose that this system paves the way for new and exciting applications for in situ analysis of small samples by NMR spectroscopy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...